-
ELECTROSURGICAL INSTRUMENTS
Unsurpassed performance and quality are the hallmarks of Valleylab™ electrosurgical pencils, and why our pencils have become the standard against which others are measured.
Force TriVerse™ electrosurgical devices allow you to access the Valleylab™ mode for a unique combination of monopolar hemostasis and dissection while using a lower power setting resulting in less char, less thermal spread and less arcing than a traditional coagulation mode. The Force TriVerse™ electrosurgical device, used in conjunction with Valleylab™ solid laparoscopic electrodes, provides performance and convenience for your laparoscopic procedures.
-
EMERALD™ Diagnostic Guidewire
Intended for percutaneous entry and guidance of catheters, the EMERALD™ Diagnostic Guidewire complements our diagnostic catheter and catheter sheath introducer lines. Performance, endurance, and safety are built into each EMERALD™ Guidewire with the solid tensile strength to minimize the likelihood of stretching or fracturing. In the unlikely event this occurs, a safety ribbon is welded to both ends of the wire to help the wire remain intact.
- Enhanced maneuverability
- Finger straightenability
- Proprietary PTFE coating process
- Available in multiple shapes and sizes
Available separately or in CORPAC™ which includes 3 diagnostic catheters, 1 sheath and 1 diagnostic guidewire.
-
External Pacemakers & Leads
4427 EASYPACE is a single chamber external pacemaker providing reliable
temporary stimulation, thanks to the microprocessor control of the parameters.
– Low battery indicator
– Standby battery for main battery replacement
– Autosense function for synchronous stimulation
– Atrial overdrive stimulation (burst and ramp)
– Antirunaway protection
– Alarm for electrode disconnection
– Impedance alarm for electrode disconnection -
Extremity Chamber AOTI
-
Flexon™ Temporary Cardiac Pacing Leads
OVERVIEW
Flexon™ temporary cardiac pacing leads are specifically designed to insulate the lead and be less traumatic during removal after pacing is complete. They are indicated for use in temporary atrial and ventricular pacing and sensing during and after cardiac surgery.ents.
-
Fred PA-1
By lifting the device cover, the FRED PA-1 starts up immediately and guides the rescuer step by step during the entire resuscitation process. The FRED PA-1 is available either as semi-automatic or fully automatic device.In its automatic version, the FRED PA-1 delivers the shock without any action of the rescuer. In its semi-automatic version, the FRED PA-1 prompts the rescuer to deliver the shock by pressing the shock button.